Блок управления генератором 14 В 50 А замена FAA PMA
Generator Control Unit 14 Volt 50 Amp FAA PMA Replacement
Артикул: 07-00619
1
От 79 629 ₽
Доступно для заказа
Цена без учёта доставки
✈️
Уточняем актуальную цену…
Note: Manufacturer C of C not available on Zeftronics stocked units. Zeftronics C of C available via special order only. If certs are required, please add part # 07-00000 with your order (See Accessories). 14V, 50A Generator Controller Unit: Delco Remy Type A Generator System Voltage Regulator G1350N 14V 50A Delco Remy Generator Voltage Regulator PMA Replacement. Whats included: Installation Drawing Warranty Card Product Eligibility Catalog (PEC) Troubleshooting Notes Instructions For Continued Airworthiness Maintenance (ICA) Voltage Regulation, IC Sense ReferencedThe Voltage Regulator (VR) controls the Generators field to keep the aircraft electrical system voltage at a specific level. This controller has a Type A regulator which excites the field of the alternator by providing controlled ground to one side of the field (F), with the other side internally connected to the armature. Electronic Controlled Generator Build-up / Automatic Field Flashing The Generator Build-up function allows the rotating generator to build-up its output from a low residual voltage to the systems voltage regulation point. G1500N 14V 50A Delco Remy Generator Voltage Regulator PMA Replacement Electronics Field Controller/Switching The VR electronics switch turns the field current on/off so fast (several times a second) that the output voltage of the generator stays at the VR set point. When the generators output voltage exceeds the VR set point, the switch opens, current flow stops, and the generators output decreases. Current Limit, IC Sensed Controlled The Current Limiter (CL) controls the maximum output current the generator can produce. It turn off the field excitation when the output current exceed the CL set point (determined by the generators current rating). It allows normal field excitation when the generator output is below the GCU CL set point. Reverse Current Protection The Reverse Current (RC) Protection circuit blocks the battery current from going back to the generator. It allows current to flow only from the generator to the battery and system. GCU induced Over Voltage (OV) Protected The GCUs design will cause the field current path (between the field and ground) to open if the field control device becomes internally ground shorted. This means that the GCU will not induce Over-Voltage (OV) problem into the system. The GCU does not protect the system against externally induced OV faults. Trouble-Shooting Lights on Unit The on-unit system Trouble-Shooting Lights, TSL, identify how the system is operating and, helps with system testing and troubleshooting. The lights indicate Generator Off/On-line (GO, GREEN), Voltage Regulation (VR, GREEN), Current Limit (CL, RED), and Parallel (EQ, or Load sharing, GREEN). Other Features: Footprint Compatible to Delco-Remys VR Increase Regulator Life Not Temperature Sensitive Prevents Regulator cycling at low RPM Eliminate Regulator Noise More Precise Current Limit Prevents Battery Current Flowing to the Generator GCU will not cause OV fault in the system Reduce Trouble-Shooting Time
Интересует 07-00619?
Отправьте запрос — уточним наличие и сроки поставки.